Trouble Code |
Fault location / Ubicacion de Falla |
Probable cause / Causas Probables |
P2201 |
Nitrogen oxides (NOx) sensor, bank 1 - range/ performance problem |
Wiring, NOx sensor |
P2202 |
Nitrogen oxides (NOx) sensor, bank 1 - low input |
Wiring short to ground, NOx sensor |
P2203 |
Nitrogen oxides (NOx) sensor, bank 1 - high input |
Wiring short to positive, NOx sensor |
P2204 |
Nitrogen oxides (NOx) sensor, bank 1 - intermittent input |
Wiring, poor connection, NOx sensor |
P2205 |
Nitrogen oxides (NOx) sensor, bank 1, heater control - open circuit |
Wiring, NOx sensor |
P2206 |
Nitrogen oxides (NOx) sensor, bank 1, heater control - circuit low |
Wiring short to ground, NOx sensor |
P2207 |
Nitrogen oxides (NOx) sensor, bank 1, heater control - circuit high |
Wiring short to positive, NOx sensor |
P2208 |
Nitrogen oxides (NOx) sensor, bank 1, heater sense circuit - malfunction |
Wiring, NOx sensor |
P2209 |
Nitrogen oxides (NOx) sensor, bank 1, heater sense circuit - range/ performance
problem |
Wiring, NOx sensor |
P220A |
Heated oxygen sensor (HO2S) 3, bank 1 - implausible signal |
Wiring, short to positive, short to ground, HO2S, ECM |
P220B |
Heated oxygen sensor (HO2S) 3, bank 1 - implausible signal |
Wiring, short to positive, short to ground, HO2S, ECM |
P220F |
Heated oxygen sensor (HO2S) 3, bank 1 - implausible signal |
Wiring, short to positive, short to ground, HO2S, ECM |
P2210 |
Nitrogen oxides (NOx)
sensor, bank 1, heater sense circuit - low input
Heated oxygen sensor
(HO2S) 3, bank 1 - implausible signal |
Wiring short to
ground, NOx sensor
Wiring, short to
positive, short to ground, HO2S, ECM |
P2211 |
Nitrogen oxides (NOx) sensor, bank 1, heater sense circuit - high input |
Wiring short to positive, NOx sensor |
P2212 |
Nitrogen oxides (NOx) sensor, bank 1, heater sense circuit - circuit
intermittent |
Wiring, poor connection, NOx sensor |
P2213 |
Nitrogen oxides (NOx) sensor, bank 2, circuit malfunction |
Wiring, NOx sensor |
P2214 |
Nitrogen oxides (NOx) sensor, bank 2 - range/ performance problem |
Wiring, NOx sensor |
P2215 |
Nitrogen oxides (NOx) sensor, bank 2, low input |
Wiring short to ground, NOx sensor |
P2216 |
Nitrogen oxides (NOx) sensor, bank 2, high input |
Wiring short to positive, NOx sensor |
P2217 |
Nitrogen oxides (NOx) sensor, bank 2 - intermittent input |
Wiring, poor connection, NOx sensor |
P2218 |
Nitrogen oxides (NOx) sensor, bank 2, heater control - open circuit |
Wiring, NOx sensor |
P2219 |
Nitrogen oxides (NOx) sensor, bank 2, heater control - circuit low |
Wiring short to ground, NOx sensor |
P221B |
Heated oxygen sensor (HO2S) 3, bank 1 - implausible signal |
Wiring, short to positive, short to ground, HO2S, ECM |
P221C |
Heated oxygen sensor (HO2S) 3, bank 1 - signal high |
Wiring, short to positive, HO2S, ECM |
P221D |
Heated oxygen sensor (HO2S) 3, bank 1 - signal low |
Wiring, short to ground, HO2S, ECM |
P2220 |
Nitrogen oxides (NOx)
sensor, bank 2, heater control - circuit high
Heated oxygen sensor
(HO2S) 3, bank 1 - implausible signal |
Wiring short to
positive, NOx sensor
Wiring, short to
positive, short to ground, HO2S, ECM |
P2221 |
Nitrogen oxides (NOx) sensor, bank 2, heater sense circuit - circuit malfunction |
Wiring, NOx sensor |
P2222 |
Nitrogen oxides (NOx) sensor, bank 2, heater sense circuit - range/ performance
problem |
Wiring, NOx sensor |
P2223 |
Nitrogen oxides (NOx) sensor, bank 2, heater sense circuit - circuit low |
Wiring short to ground, NOx sensor |
P2224 |
Nitrogen oxides (NOx) sensor, bank 2, heater sense circuit - circuit high |
Wiring short to positive, NOx sensor |
P2225 |
Nitrogen oxides (NOx) sensor, bank 2, heater sense circuit - circuit
intermittent |
Wiring, poor connection, NOx sensor |
P2226 |
Barometric pressure (BARO) sensor - circuit malfunction |
Wiring, BARO sensor, ECM |
P2227 |
Barometric pressure (BARO) sensor - range/ performance problem |
Wiring, BARO sensor, ECM |
P2228 |
Barometric pressure (BARO) sensor - circuit low |
Wiring short to ground, BARO sensor, ECM |
P2229 |
Barometric pressure (BARO) sensor - circuit high |
Wiring short to positive, BARO sensor, ECM |
P222B |
Heated oxygen sensor (HO2S) 3, bank 1 - implausible signal |
Wiring, short to positive, short to ground, HO2S, ECM |
P222C |
Heated oxygen sensor (HO2S) 3, bank 1 - signal high |
Wiring, short to positive, HO2S, ECM |
P222D |
Heated oxygen sensor (HO2S) 3, bank 1 - signal low |
Wiring, short to ground, HO2S, ECM |
P2230 |
Barometric pressure (BARO) sensor - circuit intermittent |
Wiring, poor connection, BARO sensor, ECM |
P2231 |
Heated oxygen sensor
(HO2S) 1, bank 1 - signal circuit shorted to heater circuit
Heated oxygen sensor
(HO2S) 1, bank 1 - no signal |
Wiring, HO2S
Wiring HO2S,
ECM |
P2232 |
Heated oxygen sensor
(HO2S) 2, bank 1 - signal circuit shorted to heater circuit
Heated oxygen sensor
(HO2S) 2, bank 1 - implausible signal |
Wiring, HO2S
Wiring, short to
positive, short to ground, HO2S, ECM |
P2233 |
Heated oxygen sensor (HO2S) 3, bank 1 - signal circuit shorted to heater circuit |
Wiring, HO2S |
P2234 |
Heated oxygen sensor
(HO2S) 1, bank 2 - signal circuit shorted to heater circuit
Heated oxygen sensor
(HO2S) 1, bank 2 - no signal |
Wiring, HO2S
Wiring, HO2S, ECM |
P2235 |
Heated oxygen sensor
(HO2S) 2, bank 2 - signal circuit shorted to heater circuit
Heated oxygen sensor
(HO2S) 2, bank 2 - implausible signal |
Wiring, HO2S
Wiring, short to
positive, short to ground, HO2S, ECM |
P2236 |
Heated oxygen sensor (HO2S) 3, bank 2 - signal circuit shorted to heater circuit |
Wiring, HO2S |
P2237 |
Heated oxygen sensor
(HO2S) 1, bank 1, positive current control - open circuit
Oxygen sensor (O2S) 1,
bank 1, positive current control - open circuit
Heated oxygen sensor
(HO2S) 1, bank 1 - no signal |
Wiring, HO2S
Wiring, O2S
Wiring, HO2S, ECM |
P2238 |
Heated oxygen sensor
(HO2S) 1, bank 1, positive current control - circuit low
Oxygen sensor (O2S) 1,
bank 1, positive current control - circuit low
Heated oxygen sensor
(HO2S) 1, bank 1 - implausible signal |
Wiring, short to
ground, HO2S Wiring short to
ground, O2S
Wiring, short to
positive, short to ground, HO2S, ECM |
P2239 |
Heated oxygen sensor
(HO2S) 1, bank 1, positive current control - circuit high
Oxygen sensor (O2S) 1,
bank 1, positive current control - circuit high |
Wiring short to
positive, HO2S Wiring, short to
positive, O2S |
P223B |
Heated oxygen sensor (HO2S) 3, bank 1 - implausible signal |
Wiring, short to positive, short to ground, HO2S, ECM |
P223C |
Heated oxygen sensor (HO2S) 3, bank 1 - signal high |
Wiring, short to positive, HO2S, ECM |
P223D |
Heated oxygen sensor (HO2S) 3, bank 1 - signal low |
Wiring, short to ground, HO2S, ECM |
P2240 |
Heated oxygen sensor
(HO2S) 1, bank 2, positive current control - open circuit
Oxygen sensor (O2S) 1,
bank 2, positive current control - open circuit
Heated oxygen sensor
(HO2S) 1, bank 2 - no signal |
Wiring, HO2S
Wiring, O2S
Wiring, HO2S, ECM |
P2241 |
Heated oxygen sensor
(HO2S) 1, bank 2, positive current control - circuit low
Oxygen sensor (O2S) 1,
bank 2, positive current control - circuit low
Heated oxygen sensor
(HO2S) 1, bank 2 - implausible signal |
Wiring, short to
ground, HO2S Wiring short to
ground, O2S
Wiring, short to
positive, short to ground, HO2S, ECM |
P2242 |
Heated oxygen sensor
(HO2S) 1, bank 2, positive current control - circuit high
Oxygen sensor (O2S) 1,
bank 2, positive current control - circuit high |
Wiring short to
positive, HO2S Wiring, short to
positive, O2S |
P2243 |
Heated oxygen sensor
(HO2S) 1, bank 1, reference voltage - open circuit
Oxygen sensor (O2S) 1,
bank 1, reference voltage - open circuit
Heated oxygen sensor
(HO2S) 1, bank 1 - no signal |
Wiring, HO2S
Wiring, O2S
Wiring, HO2S, ECM |
P2244 |
Heated oxygen sensor
(HO2S) 1, bank 1, reference voltage - performance problem
Oxygen sensor (O2S) 1,
bank 1, reference voltage - performance problem |
Wiring, HO2S
Wiring, O2S |
P2245 |
Heated oxygen sensor
(HO2S) 1, bank 1, reference voltage - circuit low
Oxygen sensor (O2S) 1,
bank 1, reference voltage - circuit low
|
Wiring short to
ground, HO2S Wiring short to
ground, O2S |
P2246 |
Heated oxygen sensor
(HO2S) 1, bank 1, reference voltage - circuit high
Oxygen sensor (O2S) 1,
bank 1, reference voltage - circuit high |
Wiring short to
positive, HO2S Wiring short to
positive, O2S |
P2247 |
Heated oxygen sensor
(HO2S) 1, bank 2, reference voltage - open circuit
Oxygen sensor (O2S) 1,
bank 2, reference voltage - open circuit
Heated oxygen sensor
(HO2S) 1, bank 2 - no signal |
Wiring, HO2S
Wiring, O2S
Wiring, HO2S, ECM |
P2248 |
Heated oxygen sensor
(HO2S) 1, bank 2, reference voltage - performance problem
Oxygen sensor (O2S) 1,
bank 2, reference voltage - performance problem |
Wiring, HO2S
Wiring, O2S |
P2249 |
Heated oxygen sensor
(HO2S) 1, bank 2, reference voltage - circuit low
Oxygen sensor (O2S) 1,
bank 2, reference voltage - circuit low |
Wiring short to
ground, HO2S Wiring short to
ground, O2S |
P2250 |
Heated oxygen sensor
(HO2S) 1, bank 2, reference voltage - circuit high
Oxygen sensor (O2S) 1,
bank 2, reference voltage - circuit high |
Wiring short to
positive, HO2S Wiring short to
positive, O2S |
|